ACR Inner
Grooved Copper Tubings
By producing products of advanced
technology, HALCOR is one of the few companies in Europe
that have the ability to produce inner grooved copper
tubes (ACR) with a minimum wall thickness of 0.28mm. The
said tubes are a product of advanced technology and efficiency
and are widely used in the modern air-conditioning devices
industry.
More than 50 years experience.
Advanced know-how and installations.

ACR Inner
Grooved Copper Tubings Specifications
Talos
fin high performance inner grooved tubes - sizes
and configurations
|
| Groove Type/ Met Tube Code |
Groove
Shape |
Nominal
Size |
Outside
Diameter |
Inner
Diameter |
Bottom Wall |
Groove Depth |
|
A-1 |
 |
9.52x0.35 |
9.52±0.05 |
8.66±0.03 |
0.28±0.03 |
0.15±0.02 |
| A-2 |
9.52x0.41 |
9.52±0.05 |
8.54±0.03 |
0.34±0.03 |
0.15±0.02 |
| A-7 |
7.94x0.35 |
7.94±0.05 |
7.08±0.03 |
0.28±0.03 |
0.15±0.02 |
| B-6 |
9.52x0.36 |
9.52±0.05 |
8.52±0.03 |
0.30±0.03 |
0.20±0.03 |
| B-10 |
9.52x0.35 |
9.52±0.05 |
8.66±0.03 |
0.28±0.03 |
0.15±0.02 |
| B-17 |
9.52x0.32 |
7.00±0.05 |
6.16±0.03 |
0.27±0.03 |
0.15±0.02 |
| B-18 |
6.35x0.28 |
6.35±0.05 |
5.55±0.03 |
0.2±0.03 |
0.15±0.02 |
| |
|
|
|
|
|
|
| Groove
Type/ Met Tube Code |
Groove
Shape |
Total
Wall Thickness |
No.
of Grooves |
Lead
Angle |
Top
Angle |
Unit
Weight gm/m |
| A-1 |
|
0.43±0.05 |
65 |
25±2 deg |
90 deg |
94±2gms |
| A-2 |
0.49±0.05 |
65 |
25±2 deg |
85 deg |
94±2gms |
| A-7 |
0.43±0.05 |
65 |
17±2 deg |
90 deg |
94±2gms |
| B-6 |
0.50±0.05 |
60 |
18±2 deg |
53 deg |
94±2gms |
| B-10 |
0.43±0.05 |
60 |
18±2 deg |
53 deg |
94±2gms |
| B-17 |
0.42±0.05 |
60 |
18±2 deg |
53 deg |
94±2gms |
| B-18 |
0.40±0.05 |
45 |
18±2 deg |
50 deg |
94±2gms |
| |
|
|
|
|
|
|
|